About


Entity Number: RN101812477
Entity Name: MAX E MART 6
Address: 2108 GARNER FIELD RD, UVALDE TX 78801 6216
County: UVALDE
City: UVALDE
State: TX
Zip Code: 78801
Primary Business: RETAIL
Elevation (ft): 943.79

Tags : #Entity

Location :
2108 GARNER FIELD RD, UVALDE TX 78801 6216, UVALDE, TX 78801, USA

Description

Program(s):

PST-9401
 Facility Number : 9401
 Name : MAX-E-MART 6
 Status : ACTIVE
 Type : RETAIL
 Begin Date : 1989-08-31
 Exempt Status : NO
 Records Off-Site : YES
 Financial Assurance Required : YES
 Active USTs : 3
 Active ASTs : 0
 Location Description :
 Nearest City :
 County : UVALDE
 TCEQ Region : 13
 ZIP : 78801
 Organization : MAX-E-MART 6
 Contact Name/Title : ROGER RODRIGUEZ, SUPERVISOR
 Mailing Address :
 Phone : (830) 734-3778
 Fax :
 Email :
 Deliverable Address :
 Application Received Date : 2021-01-15
 Signature Date : 2021-01-07
 Signer Name/Title : TARA MAXEY, VP
 Signer Role : LEGAL AUTH REP OWNER
 Signer Company :
 Enforcement Action : NO
 Action Date :
 Not Inspectable : NO
 Not Inspected Reason 1 :
 Not Inspected Reason 2 :
 Site City : UVALDE
 USTs
   Tank ID: 1
    Tank ID : 1
    Number of Compartments : 1
    Installation Date : 1983-01-01
    Registration Date : 1986-05-08
    Capacity : 6000
    Tank Status : IN USE
    Status Begin Date : 1983-01-01
    Is Empty : NO
    Regulatory Status : FULLY REGULATED
    Single Wall Tank : YES
    Double Wall Tank : NO
    Piping Type : PRESSURIZED
    Single Wall Piping : YES
    Double Wall Piping : NO
    Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO
    Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO
    Internal Tank Lining Date :
    Piping External Containment(Factory Nonmetallic Jacket) : NO
    Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Piping External Containment(Tank Vault/Rigid Trench Liner) : NO
    Is Steel Tank : YES
    Is FRP Tank : NO
    Is Composite Tank : NO
    Is Concrete Tank : NO
    Is Jacketed Tank : NO
    Is Coated Tank : NO
    Is Steel Piping : NO
    Is FRP Piping : YES
    Is Concrete Piping : NO
    Is Jacketed Piping : NO
    Is Nonmetallic Flex Piping : NO
    Has Piping Connector Valves(Shear/Impact) : NO
    Has Piping Connector Valves(Steel/Swing Joint) : NO
    Has Piping Connector Valves(Flexible) : NO
    Tank Corrosion Protection Method is Ext Dielectric Coating : NO
    Tank has Factory Installed Corrosion Protection : NO
    Tank has Field Installed Corrosion Protection : YES
    Tank Corrosion Protection Method is Composite : NO
    Tank Corrosion Protection Method is Coated : NO
    Tank Corrosion Protection Method is FRP : NO
    Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO
    Tank Corrosion Protection is Unecessary per Specialist : NO
    Piping Corrosion Protection is Ext Dielectric Coating : NO
    Piping has Factory Installed Corrosion Protection : NO
    Piping has Field Installed Corrosion Protection : YES
    Piping Corrosion Protection is FRP : YES
    Piping Corrosion Protection is Nonmetallic Flex : NO
    Piping Corrosion Protection is isolated in Open Area : NO
    Piping Corrosion Protection is Dual Protected : NO
    Piping Corrosion Protection is Unecessary per Specialist : NO
    Tank Corrosion Protection Compliance Flag : YES
    Piping Corrosion Protection Compliance Flag : YES
    Tank Corrosion Protection Variance : NO
    Piping Corrosion Protection Variance : NO
    Temporary Out of Service Compliant : YES
    Technical Compliance Flag : YES
    Tank Tested Flag : YES
    Signature Date : 1990-04-25
    Compartments
     Compartment ID: A
   Tank ID: 2
    Tank ID : 2
    Number of Compartments : 1
    Installation Date : 1983-01-01
    Registration Date : 1986-05-08
    Capacity : 6000
    Tank Status : IN USE
    Status Begin Date : 1983-01-01
    Is Empty : NO
    Regulatory Status : FULLY REGULATED
    Single Wall Tank : YES
    Double Wall Tank : NO
    Piping Type : PRESSURIZED
    Single Wall Piping : YES
    Double Wall Piping : NO
    Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO
    Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO
    Internal Tank Lining Date :
    Piping External Containment(Factory Nonmetallic Jacket) : NO
    Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Piping External Containment(Tank Vault/Rigid Trench Liner) : NO
    Is Steel Tank : YES
    Is FRP Tank : NO
    Is Composite Tank : NO
    Is Concrete Tank : NO
    Is Jacketed Tank : NO
    Is Coated Tank : NO
    Is Steel Piping : NO
    Is FRP Piping : YES
    Is Concrete Piping : NO
    Is Jacketed Piping : NO
    Is Nonmetallic Flex Piping : NO
    Has Piping Connector Valves(Shear/Impact) : NO
    Has Piping Connector Valves(Steel/Swing Joint) : NO
    Has Piping Connector Valves(Flexible) : NO
    Tank Corrosion Protection Method is Ext Dielectric Coating : NO
    Tank has Factory Installed Corrosion Protection : NO
    Tank has Field Installed Corrosion Protection : YES
    Tank Corrosion Protection Method is Composite : NO
    Tank Corrosion Protection Method is Coated : NO
    Tank Corrosion Protection Method is FRP : NO
    Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO
    Tank Corrosion Protection is Unecessary per Specialist : NO
    Piping Corrosion Protection is Ext Dielectric Coating : NO
    Piping has Factory Installed Corrosion Protection : NO
    Piping has Field Installed Corrosion Protection : YES
    Piping Corrosion Protection is FRP : YES
    Piping Corrosion Protection is Nonmetallic Flex : NO
    Piping Corrosion Protection is isolated in Open Area : NO
    Piping Corrosion Protection is Dual Protected : NO
    Piping Corrosion Protection is Unecessary per Specialist : NO
    Tank Corrosion Protection Compliance Flag : YES
    Piping Corrosion Protection Compliance Flag : YES
    Tank Corrosion Protection Variance : NO
    Piping Corrosion Protection Variance : NO
    Temporary Out of Service Compliant : NO
    Technical Compliance Flag : NO
    Tank Tested Flag : YES
    Signature Date : 1990-04-25
    Compartments
     Compartment ID: A
   Tank ID: 3
    Tank ID : 3
    Number of Compartments : 1
    Installation Date : 1983-01-01
    Registration Date : 1986-05-08
    Capacity : 6000
    Tank Status : IN USE
    Status Begin Date : 1983-01-01
    Is Empty : NO
    Regulatory Status : FULLY REGULATED
    Single Wall Tank : YES
    Double Wall Tank : NO
    Piping Type : PRESSURIZED
    Single Wall Piping : YES
    Double Wall Piping : NO
    Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO
    Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO
    Internal Tank Lining Date :
    Piping External Containment(Factory Nonmetallic Jacket) : NO
    Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Piping External Containment(Tank Vault/Rigid Trench Liner) : NO
    Is Steel Tank : YES
    Is FRP Tank : NO
    Is Composite Tank : NO
    Is Concrete Tank : NO
    Is Jacketed Tank : NO
    Is Coated Tank : NO
    Is Steel Piping : NO
    Is FRP Piping : YES
    Is Concrete Piping : NO
    Is Jacketed Piping : NO
    Is Nonmetallic Flex Piping : NO
    Has Piping Connector Valves(Shear/Impact) : NO
    Has Piping Connector Valves(Steel/Swing Joint) : NO
    Has Piping Connector Valves(Flexible) : NO
    Tank Corrosion Protection Method is Ext Dielectric Coating : NO
    Tank has Factory Installed Corrosion Protection : NO
    Tank has Field Installed Corrosion Protection : YES
    Tank Corrosion Protection Method is Composite : NO
    Tank Corrosion Protection Method is Coated : NO
    Tank Corrosion Protection Method is FRP : NO
    Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO
    Tank Corrosion Protection is Unecessary per Specialist : NO
    Piping Corrosion Protection is Ext Dielectric Coating : NO
    Piping has Factory Installed Corrosion Protection : NO
    Piping has Field Installed Corrosion Protection : YES
    Piping Corrosion Protection is FRP : YES
    Piping Corrosion Protection is Nonmetallic Flex : NO
    Piping Corrosion Protection is isolated in Open Area : NO
    Piping Corrosion Protection is Dual Protected : NO
    Piping Corrosion Protection is Unecessary per Specialist : NO
    Tank Corrosion Protection Compliance Flag : YES
    Piping Corrosion Protection Compliance Flag : YES
    Tank Corrosion Protection Variance : NO
    Piping Corrosion Protection Variance : NO
    Temporary Out of Service Compliant : NO
    Technical Compliance Flag : NO
    Tank Tested Flag : YES
    Signature Date : 1990-04-25
    Compartments
     Compartment ID: A
TX-TCEQ ACR-RN101812477
 Program ID : RN101812477
 Registry ID : 110034853479
 Program Type : STATE MASTER
 Program Status :
 Federal State Code : STATE
 Facility Name : MAX E MART 6
 Location Address : 2108 GARNER FIELD RD
 Supplemental Location :
 City : UVALDE
 County : UVALDE
 FIPS Code : 48463
 State Code : TX
 Country : UNITED STATES
 ZIP Code : 788016216
 Congressional Dist Num : 23
 Census Block Code : 484639502006058
 HUC Code : 12110106
 EPA Region Code : 06
 Site Type Name : STATIONARY
 Location Description :
 US Mexico Border : Yes
 Program Acronyms : TX-TCEQ ACR:RN101812477
 Conveyor : FRS-GEOCODE
 Collect Description : ADDRESS MATCHING-HOUSE NUMBER
 Ref Point Description : CENTER OF A FACILITY OR STATION
 HDATUM Description : NAD83
 Source Description :
 Coordinate : 29.21905,-99.7487
 Accuracy : 30
 Federal Facility Code :
 Federal Agency Code :
 Tribal Land Code :
 Tribal Land Name :
 Legislative Dist Num :
 Data Quality Code : Valid
 NAICS
   No Data :
 SIC
   No Data :
 Organization
 Alternative-Names
 Contact
   No Data :
 Mailing-Address
   No Data :