Program(s):
PST-9401 | ||||||||
Facility Number : 9401 | ||||||||
Name : MAX-E-MART 6 | ||||||||
Status : ACTIVE | ||||||||
Type : RETAIL | ||||||||
Begin Date : 1989-08-31 | ||||||||
Exempt Status : NO | ||||||||
Records Off-Site : YES | ||||||||
Financial Assurance Required : YES | ||||||||
Active USTs : 3 | ||||||||
Active ASTs : 0 | ||||||||
Location Description : | ||||||||
Nearest City : | ||||||||
County : UVALDE | ||||||||
TCEQ Region : 13 | ||||||||
ZIP : 78801 | ||||||||
Organization : MAX-E-MART 6 | ||||||||
Contact Name/Title : ROGER RODRIGUEZ, SUPERVISOR | ||||||||
Mailing Address : | ||||||||
Phone : (830) 734-3778 | ||||||||
Fax : | ||||||||
Email : | ||||||||
Deliverable Address : | ||||||||
Application Received Date : 2021-01-15 | ||||||||
Signature Date : 2021-01-07 | ||||||||
Signer Name/Title : TARA MAXEY, VP | ||||||||
Signer Role : LEGAL AUTH REP OWNER | ||||||||
Signer Company : | ||||||||
Enforcement Action : NO | ||||||||
Action Date : | ||||||||
Not Inspectable : NO | ||||||||
Not Inspected Reason 1 : | ||||||||
Not Inspected Reason 2 : | ||||||||
Site City : UVALDE | ||||||||
USTs | ||||||||
Tank ID: 1 | ||||||||
Tank ID : 1 | ||||||||
Number of Compartments : 1 | ||||||||
Installation Date : 1983-01-01 | ||||||||
Registration Date : 1986-05-08 | ||||||||
Capacity : 6000 | ||||||||
Tank Status : IN USE | ||||||||
Status Begin Date : 1983-01-01 | ||||||||
Is Empty : NO | ||||||||
Regulatory Status : FULLY REGULATED | ||||||||
Single Wall Tank : YES | ||||||||
Double Wall Tank : NO | ||||||||
Piping Type : PRESSURIZED | ||||||||
Single Wall Piping : YES | ||||||||
Double Wall Piping : NO | ||||||||
Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO | ||||||||
Internal Tank Lining Date : | ||||||||
Piping External Containment(Factory Nonmetallic Jacket) : NO | ||||||||
Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Piping External Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Is Steel Tank : YES | ||||||||
Is FRP Tank : NO | ||||||||
Is Composite Tank : NO | ||||||||
Is Concrete Tank : NO | ||||||||
Is Jacketed Tank : NO | ||||||||
Is Coated Tank : NO | ||||||||
Is Steel Piping : NO | ||||||||
Is FRP Piping : YES | ||||||||
Is Concrete Piping : NO | ||||||||
Is Jacketed Piping : NO | ||||||||
Is Nonmetallic Flex Piping : NO | ||||||||
Has Piping Connector Valves(Shear/Impact) : NO | ||||||||
Has Piping Connector Valves(Steel/Swing Joint) : NO | ||||||||
Has Piping Connector Valves(Flexible) : NO | ||||||||
Tank Corrosion Protection Method is Ext Dielectric Coating : NO | ||||||||
Tank has Factory Installed Corrosion Protection : NO | ||||||||
Tank has Field Installed Corrosion Protection : YES | ||||||||
Tank Corrosion Protection Method is Composite : NO | ||||||||
Tank Corrosion Protection Method is Coated : NO | ||||||||
Tank Corrosion Protection Method is FRP : NO | ||||||||
Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO | ||||||||
Tank Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Piping Corrosion Protection is Ext Dielectric Coating : NO | ||||||||
Piping has Factory Installed Corrosion Protection : NO | ||||||||
Piping has Field Installed Corrosion Protection : YES | ||||||||
Piping Corrosion Protection is FRP : YES | ||||||||
Piping Corrosion Protection is Nonmetallic Flex : NO | ||||||||
Piping Corrosion Protection is isolated in Open Area : NO | ||||||||
Piping Corrosion Protection is Dual Protected : NO | ||||||||
Piping Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Tank Corrosion Protection Compliance Flag : YES | ||||||||
Piping Corrosion Protection Compliance Flag : YES | ||||||||
Tank Corrosion Protection Variance : NO | ||||||||
Piping Corrosion Protection Variance : NO | ||||||||
Temporary Out of Service Compliant : YES | ||||||||
Technical Compliance Flag : YES | ||||||||
Tank Tested Flag : YES | ||||||||
Signature Date : 1990-04-25 | ||||||||
Compartments | ||||||||
Compartment ID: A | ||||||||
Tank ID: 2 | ||||||||
Tank ID : 2 | ||||||||
Number of Compartments : 1 | ||||||||
Installation Date : 1983-01-01 | ||||||||
Registration Date : 1986-05-08 | ||||||||
Capacity : 6000 | ||||||||
Tank Status : IN USE | ||||||||
Status Begin Date : 1983-01-01 | ||||||||
Is Empty : NO | ||||||||
Regulatory Status : FULLY REGULATED | ||||||||
Single Wall Tank : YES | ||||||||
Double Wall Tank : NO | ||||||||
Piping Type : PRESSURIZED | ||||||||
Single Wall Piping : YES | ||||||||
Double Wall Piping : NO | ||||||||
Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO | ||||||||
Internal Tank Lining Date : | ||||||||
Piping External Containment(Factory Nonmetallic Jacket) : NO | ||||||||
Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Piping External Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Is Steel Tank : YES | ||||||||
Is FRP Tank : NO | ||||||||
Is Composite Tank : NO | ||||||||
Is Concrete Tank : NO | ||||||||
Is Jacketed Tank : NO | ||||||||
Is Coated Tank : NO | ||||||||
Is Steel Piping : NO | ||||||||
Is FRP Piping : YES | ||||||||
Is Concrete Piping : NO | ||||||||
Is Jacketed Piping : NO | ||||||||
Is Nonmetallic Flex Piping : NO | ||||||||
Has Piping Connector Valves(Shear/Impact) : NO | ||||||||
Has Piping Connector Valves(Steel/Swing Joint) : NO | ||||||||
Has Piping Connector Valves(Flexible) : NO | ||||||||
Tank Corrosion Protection Method is Ext Dielectric Coating : NO | ||||||||
Tank has Factory Installed Corrosion Protection : NO | ||||||||
Tank has Field Installed Corrosion Protection : YES | ||||||||
Tank Corrosion Protection Method is Composite : NO | ||||||||
Tank Corrosion Protection Method is Coated : NO | ||||||||
Tank Corrosion Protection Method is FRP : NO | ||||||||
Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO | ||||||||
Tank Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Piping Corrosion Protection is Ext Dielectric Coating : NO | ||||||||
Piping has Factory Installed Corrosion Protection : NO | ||||||||
Piping has Field Installed Corrosion Protection : YES | ||||||||
Piping Corrosion Protection is FRP : YES | ||||||||
Piping Corrosion Protection is Nonmetallic Flex : NO | ||||||||
Piping Corrosion Protection is isolated in Open Area : NO | ||||||||
Piping Corrosion Protection is Dual Protected : NO | ||||||||
Piping Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Tank Corrosion Protection Compliance Flag : YES | ||||||||
Piping Corrosion Protection Compliance Flag : YES | ||||||||
Tank Corrosion Protection Variance : NO | ||||||||
Piping Corrosion Protection Variance : NO | ||||||||
Temporary Out of Service Compliant : NO | ||||||||
Technical Compliance Flag : NO | ||||||||
Tank Tested Flag : YES | ||||||||
Signature Date : 1990-04-25 | ||||||||
Compartments | ||||||||
Compartment ID: A | ||||||||
Tank ID: 3 | ||||||||
Tank ID : 3 | ||||||||
Number of Compartments : 1 | ||||||||
Installation Date : 1983-01-01 | ||||||||
Registration Date : 1986-05-08 | ||||||||
Capacity : 6000 | ||||||||
Tank Status : IN USE | ||||||||
Status Begin Date : 1983-01-01 | ||||||||
Is Empty : NO | ||||||||
Regulatory Status : FULLY REGULATED | ||||||||
Single Wall Tank : YES | ||||||||
Double Wall Tank : NO | ||||||||
Piping Type : PRESSURIZED | ||||||||
Single Wall Piping : YES | ||||||||
Double Wall Piping : NO | ||||||||
Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO | ||||||||
Internal Tank Lining Date : | ||||||||
Piping External Containment(Factory Nonmetallic Jacket) : NO | ||||||||
Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO | ||||||||
Piping External Containment(Tank Vault/Rigid Trench Liner) : NO | ||||||||
Is Steel Tank : YES | ||||||||
Is FRP Tank : NO | ||||||||
Is Composite Tank : NO | ||||||||
Is Concrete Tank : NO | ||||||||
Is Jacketed Tank : NO | ||||||||
Is Coated Tank : NO | ||||||||
Is Steel Piping : NO | ||||||||
Is FRP Piping : YES | ||||||||
Is Concrete Piping : NO | ||||||||
Is Jacketed Piping : NO | ||||||||
Is Nonmetallic Flex Piping : NO | ||||||||
Has Piping Connector Valves(Shear/Impact) : NO | ||||||||
Has Piping Connector Valves(Steel/Swing Joint) : NO | ||||||||
Has Piping Connector Valves(Flexible) : NO | ||||||||
Tank Corrosion Protection Method is Ext Dielectric Coating : NO | ||||||||
Tank has Factory Installed Corrosion Protection : NO | ||||||||
Tank has Field Installed Corrosion Protection : YES | ||||||||
Tank Corrosion Protection Method is Composite : NO | ||||||||
Tank Corrosion Protection Method is Coated : NO | ||||||||
Tank Corrosion Protection Method is FRP : NO | ||||||||
Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO | ||||||||
Tank Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Piping Corrosion Protection is Ext Dielectric Coating : NO | ||||||||
Piping has Factory Installed Corrosion Protection : NO | ||||||||
Piping has Field Installed Corrosion Protection : YES | ||||||||
Piping Corrosion Protection is FRP : YES | ||||||||
Piping Corrosion Protection is Nonmetallic Flex : NO | ||||||||
Piping Corrosion Protection is isolated in Open Area : NO | ||||||||
Piping Corrosion Protection is Dual Protected : NO | ||||||||
Piping Corrosion Protection is Unecessary per Specialist : NO | ||||||||
Tank Corrosion Protection Compliance Flag : YES | ||||||||
Piping Corrosion Protection Compliance Flag : YES | ||||||||
Tank Corrosion Protection Variance : NO | ||||||||
Piping Corrosion Protection Variance : NO | ||||||||
Temporary Out of Service Compliant : NO | ||||||||
Technical Compliance Flag : NO | ||||||||
Tank Tested Flag : YES | ||||||||
Signature Date : 1990-04-25 | ||||||||
Compartments | ||||||||
Compartment ID: A | ||||||||
TX-TCEQ ACR-RN101812477 | ||||||||
Program ID : RN101812477 | ||||||||
Registry ID : 110034853479 | ||||||||
Program Type : STATE MASTER | ||||||||
Program Status : | ||||||||
Federal State Code : STATE | ||||||||
Facility Name : MAX E MART 6 | ||||||||
Location Address : 2108 GARNER FIELD RD | ||||||||
Supplemental Location : | ||||||||
City : UVALDE | ||||||||
County : UVALDE | ||||||||
FIPS Code : 48463 | ||||||||
State Code : TX | ||||||||
Country : UNITED STATES | ||||||||
ZIP Code : 788016216 | ||||||||
Congressional Dist Num : 23 | ||||||||
Census Block Code : 484639502006058 | ||||||||
HUC Code : 12110106 | ||||||||
EPA Region Code : 06 | ||||||||
Site Type Name : STATIONARY | ||||||||
Location Description : | ||||||||
US Mexico Border : Yes | ||||||||
Program Acronyms : TX-TCEQ ACR:RN101812477 | ||||||||
Conveyor : FRS-GEOCODE | ||||||||
Collect Description : ADDRESS MATCHING-HOUSE NUMBER | ||||||||
Ref Point Description : CENTER OF A FACILITY OR STATION | ||||||||
HDATUM Description : NAD83 | ||||||||
Source Description : | ||||||||
Coordinate : 29.21905,-99.7487 | ||||||||
Accuracy : 30 | ||||||||
Federal Facility Code : | ||||||||
Federal Agency Code : | ||||||||
Tribal Land Code : | ||||||||
Tribal Land Name : | ||||||||
Legislative Dist Num : | ||||||||
Data Quality Code : Valid | ||||||||
NAICS | ||||||||
No Data : | ||||||||
SIC | ||||||||
No Data : | ||||||||
Organization | ||||||||
Alternative-Names | ||||||||
Contact | ||||||||
No Data : | ||||||||
Mailing-Address | ||||||||
No Data : |