Description

Program(s):

LPSTRMD-115928
 LPST ID : 115928
 Entity Number : RN101722221
 PST Facility ID : 41847
 Site Name : BROWNIES 2
 Site Address : 1322 UNDERWOOD RD
 Site City : LA PORTE
 Near City : DEER PARK
 Site County : HARRIS
 Site ZIP : 77571
 Project Manager : THAMMITT
 Discovered Date : 2003-06-30
 Reported Date : 2003-07-23
 Entered Date : 2004-04-13
 Closure Date : 3000-12-31
 Program : 3 - STATE LEAD
 Priority Status : 4.1 - GW IMPACTED NO APPARENT THREATS OR IMPACTS TO RECEPTORS
 Corrective Action Status : 3 - MONITORING
 TCEQ Region : REGION 12 - HOUSTON
PST-41847
 Facility Number : 41847
 Name : BROWNIES MARKET 2
 Status : INACTIVE
 Type : RETAIL
 Begin Date : 1987-01-26
 Exempt Status : NO
 Records Off-Site : NO
 Financial Assurance Required : NO
 Active USTs : 0
 Active ASTs : 0
 Location Description :
 Nearest City :
 County : HARRIS
 TCEQ Region : 12
 ZIP : 77571
 Organization : BROWNIES MARKET 2
 Contact Name/Title : NOORALI J ALI
 Mailing Address :
 Phone : (281) 479-6939
 Fax :
 Email :
 Deliverable Address :
 Application Received Date : 1986-05-08
 Signature Date : 1986-04-15
 Signer Name/Title : B G METHVIN, MGR.
 Signer Role :
 Signer Company :
 Enforcement Action :
 Action Date :
 Not Inspectable : NO
 Not Inspected Reason 1 :
 Not Inspected Reason 2 :
 Site City : LA PORTE
 USTs
   Tank ID: 1
    Tank ID : 1
    Number of Compartments : 1
    Installation Date : 1979-01-01
    Registration Date : 1986-05-08
    Capacity : 8000
    Tank Status : REMOVED FROM GROUND
    Status Begin Date : 2003-01-01
    Is Empty : NO
    Regulatory Status : FULLY REGULATED
    Single Wall Tank : YES
    Double Wall Tank : NO
    Piping Type : PRESSURIZED
    Single Wall Piping : YES
    Double Wall Piping : NO
    Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO
    Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO
    Internal Tank Lining Date :
    Piping External Containment(Factory Nonmetallic Jacket) : NO
    Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Piping External Containment(Tank Vault/Rigid Trench Liner) : NO
    Is Steel Tank : YES
    Is FRP Tank : NO
    Is Composite Tank : NO
    Is Concrete Tank : NO
    Is Jacketed Tank : NO
    Is Coated Tank : NO
    Is Steel Piping : NO
    Is FRP Piping : NO
    Is Concrete Piping : YES
    Is Jacketed Piping : NO
    Is Nonmetallic Flex Piping : NO
    Has Piping Connector Valves(Shear/Impact) : NO
    Has Piping Connector Valves(Steel/Swing Joint) : NO
    Has Piping Connector Valves(Flexible) : NO
    Tank Corrosion Protection Method is Ext Dielectric Coating : NO
    Tank has Factory Installed Corrosion Protection : NO
    Tank has Field Installed Corrosion Protection : NO
    Tank Corrosion Protection Method is Composite : NO
    Tank Corrosion Protection Method is Coated : NO
    Tank Corrosion Protection Method is FRP : NO
    Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO
    Tank Corrosion Protection is Unecessary per Specialist : NO
    Piping Corrosion Protection is Ext Dielectric Coating : NO
    Piping has Factory Installed Corrosion Protection : NO
    Piping has Field Installed Corrosion Protection : NO
    Piping Corrosion Protection is FRP : YES
    Piping Corrosion Protection is Nonmetallic Flex : NO
    Piping Corrosion Protection is isolated in Open Area : NO
    Piping Corrosion Protection is Dual Protected : NO
    Piping Corrosion Protection is Unecessary per Specialist : NO
    Tank Corrosion Protection Compliance Flag : NO
    Piping Corrosion Protection Compliance Flag : YES
    Tank Corrosion Protection Variance : NO
    Piping Corrosion Protection Variance : NO
    Temporary Out of Service Compliant : NO
    Technical Compliance Flag : NO
    Tank Tested Flag : YES
    Signature Date : 1990-07-18
    Compartments
     Compartment ID: A
   Tank ID: 2
    Tank ID : 2
    Number of Compartments : 1
    Installation Date : 1979-01-01
    Registration Date : 1986-05-08
    Capacity : 8000
    Tank Status : REMOVED FROM GROUND
    Status Begin Date : 2003-01-01
    Is Empty : NO
    Regulatory Status : FULLY REGULATED
    Single Wall Tank : YES
    Double Wall Tank : NO
    Piping Type : PRESSURIZED
    Single Wall Piping : YES
    Double Wall Piping : NO
    Tank Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Tank Ext Containment(Tank Vault/Rigid Trench Liner) : NO
    Tank Ext Containment(Factory-Built Nonmetallic Jacket) : NO
    Internal Tank Lining Date :
    Piping External Containment(Factory Nonmetallic Jacket) : NO
    Piping Ext Containment(Syn Tank-Pit/Piping-Trench Liner) : NO
    Piping External Containment(Tank Vault/Rigid Trench Liner) : NO
    Is Steel Tank : YES
    Is FRP Tank : NO
    Is Composite Tank : NO
    Is Concrete Tank : NO
    Is Jacketed Tank : NO
    Is Coated Tank : NO
    Is Steel Piping : NO
    Is FRP Piping : YES
    Is Concrete Piping : NO
    Is Jacketed Piping : NO
    Is Nonmetallic Flex Piping : NO
    Has Piping Connector Valves(Shear/Impact) : NO
    Has Piping Connector Valves(Steel/Swing Joint) : NO
    Has Piping Connector Valves(Flexible) : NO
    Tank Corrosion Protection Method is Ext Dielectric Coating : NO
    Tank has Factory Installed Corrosion Protection : NO
    Tank has Field Installed Corrosion Protection : NO
    Tank Corrosion Protection Method is Composite : NO
    Tank Corrosion Protection Method is Coated : NO
    Tank Corrosion Protection Method is FRP : NO
    Tank Corrosion Protection Method is Ext Nonmetalic Jacket : NO
    Tank Corrosion Protection is Unecessary per Specialist : NO
    Piping Corrosion Protection is Ext Dielectric Coating : NO
    Piping has Factory Installed Corrosion Protection : NO
    Piping has Field Installed Corrosion Protection : NO
    Piping Corrosion Protection is FRP : YES
    Piping Corrosion Protection is Nonmetallic Flex : NO
    Piping Corrosion Protection is isolated in Open Area : NO
    Piping Corrosion Protection is Dual Protected : NO
    Piping Corrosion Protection is Unecessary per Specialist : NO
    Tank Corrosion Protection Compliance Flag : NO
    Piping Corrosion Protection Compliance Flag : YES
    Tank Corrosion Protection Variance : NO
    Piping Corrosion Protection Variance : NO
    Temporary Out of Service Compliant : NO
    Technical Compliance Flag : NO
    Tank Tested Flag : YES
    Signature Date : 1990-07-18
    Compartments
     Compartment ID: A